| T [°C] | Ua [V] | UT [V] | Fehler [%] | ![]() |
5 |
0.713 |
0.465 |
0.88 |
|
10 |
0.842 |
0.967 |
0.83 |
|
15 |
0.976 |
1.487 |
0.33 |
|
20 |
1.112 |
2.018 |
0.45 |
|
25 |
1.250 |
2.540 |
1.00 |
|
30 |
1.381 |
3.058 |
1.45 |
|
35 |
1.507 |
3.560 |
1.50 |
Gleichung zur Berechnung der Widerstandes
mit
R(T) Widerstand bei der Temperatur T-273,15
Rs Widerstand bei T = 298,15 K
T Temperatur in Kelvin
Ts Bezugstemperatur = 298,15 K
B B-Wert nach Datenblatt (2000 .. 12000)
Die untere Tabelle zeigt die normalisierten Werte
Temperatur Sensor - NTC Typ 703 |
|||||
| Tempearatur T | B25/100=3920K |
Tempearatur T | B25/100=3920K |
||
| °C | RT/R25 | aT(%/K) | °C | RT/R25 | aT(%/K) |
| -60.0 -55.0 -50.0 -45.0 -40.0
-35.0
-10.0
15.0
40.0 |
- 97.762 61.922 44.168 31.833
23.173
5.4270
1.5623
0.53922 |
- 7.1 6.9 6.7 6.5
6.3
5.5
4.6
4.0 |
65.0 70.0 75.0 80.0 85.0
90.0
115.0
140.0
165.0 |
0.21457 0.18131 0.15360 0.13064 0.11155
0.095606
0.146970
0.024955
0.014132 |
3.4 3.4 3.3 3.2 3.1
3.0
2.7
2.4
2.2 |
Hier noch die Umkehrfunktion
Berechnung des B-Wertes
Der B-Wert wird bestimmt durch eine Messung bei der Temperatur von 25°C und 100°C durch folgende Gleichung bestimmt:
B57703
| Climatic category (IEC 68-1) Max. power at 35°C Resistance tolerance Rated temperature B value tolerance Dissipation factor (in air) Thermal cooling time constant (in air) Heat capacity |
55/125/21 150 +/- 2% 25 +/- 1% approx. 2,6 approx. 28 approx. 73 |
mW °C mW/K s mJ/K |
R25 |
B25/100 |
| 5k 10k 30k |
3988 3988 3964 |
B57164
| Climatic category (IEC 68-1) Max. power at 35°C Resistance tolerance Rated temperature B value tolerance Dissipation factor (in air) Thermal cooling time constant (in air) Heat capacity |
55/125/21 450 +/- 5%, +/- 10% 25 +/- 3% approx. 7,5 approx. 20 approx. 150 |
mW °C mW/K s mJ/K |
R25 |
B25/100 |
R25 |
B25/100 |
R25 |
B25/100 |
||
| 15 22 33 47 68 100 150 220 330 |
2900 2900 2900 3000 3050 3200 3200 3200 3450 |
470 1k 1,5k 2,2k 3,3k 4,7k 6,8k 10k 15k |
3450 3730 3900 3900 3950 3950 4200 4300 4250 |
22k 33k 47k 68k 100k 150k 220k 330k 470k |
4300 4300 4450 4600 4600 4600 4830 5000 5000 |
B57045
| Climatic category (IEC 68-1) Max. power at 35°C Resistance tolerance Rated temperature B value tolerance Dissipation factor (in air) Thermal cooling time constant (in air) Thermal cooling time constant (on chassis) |
55/125/56 450 +/- 10% 25 +/- 3% approx. 9 approx. 75 approx. 15 |
mW °C mW/K s s |
R25 |
B25/100 |
| 1k 2,2k 4,7k 6,8k 10k 33k 47k 68k 100k 150k |
3730 3900 3950 4200 4300 4300 4450 4600 4600 4600 |